We don’t post pretty theory. We post what actually works on the lift at 11 PM when the customer is waiting outside with a truck full of goods and a deadline. This is the exact procedure we have refined over 15 years and literally thousands of vehicles. It works on every Bosch EDC17, EDC17C, EDC17CV, MD1, DCU17, MED17.9 – everything we have ever touched. If you follow this exactly, you will have zero comebacks. If you skip even one small thing, you will be the one on the phone at midnight call.
Step 1 – Diagnosis & Prep (the step 90 % of people completely fuck up)
- Full system scan with professional tool (Autel MS909, Bosch KTS, Launch X431 – no cheap Chinese toys).
- Write down every single DTC, even the stupid ones like “glow plug relay”.
- Check AdBlue level in tank – fill it to 100 % (yes, really). We have seen empty tank + new file = instant P20E8 + limp mode after 20 km.
- Check battery voltage – must be >12.6 V during flashing, better 14 V with charger.
- Take photo of firmware version and hardware number of the ECU.
- If the car is already in countdown (e.g. “10 starts remaining”), first flash a stage 1 file that only removes the countdown, drive 50 km, then do the full OFF. Otherwise the countdown can stay locked in memory.
Step 2 – ECU Reading (never trust OBD on Bosch after 2016)
- EDC17Cxx / MD1 / MED17.9 → always bench or boot mode. OBD is too slow and fails 30 % of the time.
- EDC17CPxx (BMW) → bench or OBD with KTAG in boot if it has Tricore password.
- EDC17CVxx (trucks & tractors) → usually OBD with KESS V2 clone works fine, but have bench cable ready.
- DCU17 units (Bobcat, Hyundai machines) → bench only.
- Read FULL flash (4–8 MB) + EEPROM if separate (Bosch usually 95640/95160).
- Save 3 copies with date + vehicle reg in the filename. We learned this after losing a Porsche Cayenne file in 2017.
Step 3 – Software Modification (where the money is made)
This is the part nobody shows on YouTube because it’s actual work.
WinOLS procedure we use every day:
- Open original file → Project → New → load file. 2 Switch to 2D/3D view and find the famous “SCR Efficiency Map” (usually around address 0x1Axxxx–0x1Cxxxx in EDC17). 3 Find the switch “SCR System Active” – set to 0. 4 Find dosing quantity map → set whole map to 0.000 g/s. 5 Find AdBlue pressure map → set to constant 0 bar (or 5 bar fake value on some MD1). 6 Find NOx sensor plausibility maps (upstream & downstream) → set thresholds to 2000 ppm (impossible value). 7 Find torque reduction maps for AdBlue faults → set multiplier to 1.00 (no reduction). 8 Find DTC mask tables (usually 3 tables):
- P20EE, P20E8, P207F, P204F, P229F, P22A7, U029D, U029E, P13DF, P20B9 etc. → set all bits to 0 or move the codes to “not relevant”. 9 Temperature correction maps (heater control) → set to 0. 10 Emergency running mode maps → disable torque limiter. 11 Checksum correction – always OEM style (Bosch Tricore is very strict).
- Open original file → Project → New → load file. 2 Switch to 2D/3D view and find the famous “SCR Efficiency Map” (usually around address 0x1Axxxx–0x1Cxxxx in EDC17). 3 Find the switch “SCR System Active” – set to 0. 4 Find dosing quantity map → set whole map to 0.000 g/s. 5 Find AdBlue pressure map → set to constant 0 bar (or 5 bar fake value on some MD1). 6 Find NOx sensor plausibility maps (upstream & downstream) → set thresholds to 2000 ppm (impossible value). 7 Find torque reduction maps for AdBlue faults → set multiplier to 1.00 (no reduction). 8 Find DTC mask tables (usually 3 tables):
For MD1CP014 / MD1CS004 (newer VAG & Porsche) you also have to patch the fraud detection routine at address ~0xAxxxxx – otherwise the ECU re-enables AdBlue after 500–1000 km.
We keep ready-made .ols project files for the 50 most common ECUs. If you don’t have them – pay us 20 € and we send you the finished file. Seriously.
Physical Disconnections (the step that separates pros from YouTube heroes)
If you leave anything connected, you will get DTCs. Guaranteed.
Standard disconnect list (memorise it):
- AdBlue pump power plug (usually brown/white wire)
- AdBlue injector plug
- Both NOx sensors (upstream + downstream) – unplug and tape the connectors
- Tank level sensor + temperature sensor plug (on some vehicles)
- AdBlue quality sensor (if present)
- DCU17 unit itself (on machines like Bobcat, Hyundai, Case) – completely remove power
- Pull fuse F12 or relay R9 in the fuse box if the vehicle has one for SCR heater
Step 5 – Flashing & First Start
- Flash the modified file (bench or OBD).
- Do NOT start the engine immediately.
- Disconnect battery for exactly 15 minutes (clears adaptations).
- Reconnect battery → ignition ON for 60 seconds → start engine → let idle 5 minutes.
- Scan again – there must be ZERO DTCs. If you see even one AdBlue code → you missed something in Step 3 or 4.
Step 6 – Road Test & Final Verification
- Drive minimum 50 km with full load (highway, uphill).
- Log NOx sensor values with scanner – both sensors must show almost identical values (e.g. 20–40 ppm).
- Check torque request in live data – must be 100 % when you floor it.
- Cold start test next morning – many hidden faults only appear after 8+ hours standstill.
Bonus: Our Personal “Never-Fail” Checklist (printed in every bay)
□ Tank filled 100 % before work □ Full read + 3 backups □ All SCR maps zeroed □ All relevant DTCs masked □ Pump, injector, both NOx sensors, DCU disconnected □ Battery disconnected 15 min after flash □ 50 km test drive logged □ Customer informed: no TÜV/MOT, off-road only